Home›Repair guides›Fischer Panda›Winter storage preparation

Fischer Panda Panda 4000s PMS FC / Panda 4000s PMS SC — Winter storage preparation

Maintenance · Generator

For the Fischer Panda Panda 4000s PMS FC / Panda 4000s PMS SC, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda_4000s, Fischer Panda Panda_4000s SC PMS, Farymann 18W430 engine

Procedure

  1. Rinse raw water circuit with an anti-freeze solution.
  2. Check anti-freeze concentration in internal cooling circuit.
  3. Clean raw water filter and check seal.
  4. Check water cock; spray with corrosion protection oil or lubricate with acidless grease.
  5. Check all hoses and hose connectors.
  6. Check hose connectors at raw water valves; protect with double hose clamps if possible.
  7. Dismount impeller; check for wear; grease with vaseline and store in dark place.
  8. Control vent valve at raw water inlet; disassemble, check and grease.
  9. Check water lock; drain water if fresh water rinse used.
  10. Check exhaust/water separator for leakage.
  11. Check all components inside sound cover for leakages; dry cover.
  12. During winter storage, take off upper sound cover section to avoid condensation.
  13. Spray generator housing and engine housing with corrosion protection oil.
  14. Disconnect starter battery positive and negative pole.
  15. Lubricate spindle for revolutions adjustment device with Antiseize grease.

Full service-parts list: Fischer Panda Panda_4000s →, Fischer Panda Panda_4000s SC PMS →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →