Home›Repair guides›Fischer Panda›Discharge capacitors

Fischer Panda Panda 4000s PMS FC / Panda 4000s PMS SC — Discharge capacitors

Maintenance · AC control box

For the Fischer Panda Panda 4000s PMS FC / Panda 4000s PMS SC, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda_4000s, Fischer Panda Panda_4000s SC PMS, Farymann 18W430 engine

Before you start

  • Never check capacitors while generator motor is running. Charged capacitors can be lethal.

Procedure

  1. Switch off generator.
  2. Disconnect starter battery.
  3. Open generator power terminal box and remove caps.
  4. Short circuit the two capacitor contacts using insulated screwdriver cone end.
  5. For three-phase capacitors discharge between every phase L1-L2, L2-L3, L1-L3.

Tools required

  • insulated screwdriver Amazon
  • discharge reactor 5-10 kOhm Amazon
  • multimeter with capacitor measuring Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Discharge reactor 5-10 kOhm.

Full service-parts list: Fischer Panda Panda_4000s →, Fischer Panda Panda_4000s SC PMS →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.