Home›Repair guides›Fischer Panda›Discharge the capacitors

Fischer Panda — Discharge the capacitors

Testing & diagnosis · AC control box capacitors

From a Fischer Panda operator's manual covering: 4000, 4000s SC, Panda 4000s PMS FC, Panda 4000s PMS SC. Check it applies to your exact model before use.

Applies to: Fischer Panda 4000, Fischer Panda 4000s SC, Fischer Panda Panda_4000s, Farymann 18W430 engine

Before you start

  • Never work at the electrical cabinet when the generator is running.
  • Do not contact the capacitor before it is discharged.

Procedure

  1. Switch off generator.
  2. Disconnect starter battery.
  3. Open generator power terminal box and remove caps.
  4. Short circuit the two capacitor contacts using the cone end of an isolated screwdriver.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →