Home›Repair guides›Fischer Panda›De-aerating of the coolant circuit / freshwater

Fischer Panda — De-aerating of the coolant circuit / freshwater

Maintenance · cooling system

From a Fischer Panda service manual covering: AGT-DC 10000, AGT10.000-24, PMS AGT-DC 10000, Panda PMS AGT-DC 10000. Check it applies to your exact model before use.

Applies to: Fischer Panda AGT-DC 10000, Fischer Panda Panda PMS AGT-DC 10000, Kubota D722 engine

Before you start

  • Generator must be stagnant before opening de-aerating points.
  • Do not open cooling water pump de-aerating screw while generator runs.

Procedure

  1. Open de-aerating screw at cooling water pump.
  2. Open de-aerating screw at thermostat housing.
  3. Fill cooling water at filler neck until level stops falling.
  4. Close filler cap and de-aerating screws.
  5. Start generator and run for max. 60 seconds.
  6. Stop generator and repeat procedure several times.

Full service-parts list: Fischer Panda AGT-DC 10000 →, Fischer Panda Panda PMS AGT-DC 10000 →, Kubota D722 engine →

Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.