Fischer Panda — Connection of the 12V starter battery
Installation
From a Fischer Panda operator's manual covering: 4000, 4000s SC, Panda 4000s PMS FC, Panda 4000s PMS SC. Check it applies to your exact model before use.
Applies to: Fischer Panda 4000, Fischer Panda 4000s SC, Fischer Panda Panda_4000s, Farymann 18W430 engine
Before you start
- Do not disconnect the battery during operation.
Procedure
- Connect positive battery cable directly to solenoid switch of starter; use prepared protective tube.
- Connect negative battery cable to connection point at engine foot.
- Install a right-sized fuse in positive battery line as close as possible to battery, maximum 12 inch or 300 mm.
- Use multi-core stranded wire only; protect cable from heat, vibration and chafing.
- Check battery cable after installation for possible damage.
Specs & values
- Battery capacity at least 44Ah
- Cable cross-section 25mm²
- Fuse maximum 12 inch or 300 mm from battery
Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.