Fischer Panda — Connection of the 12V starter battery

Installation

From a Fischer Panda operator's manual covering: 4000, 4000s SC, Panda 4000s PMS FC, Panda 4000s PMS SC. Check it applies to your exact model before use.

Applies to: Fischer Panda 4000, Fischer Panda 4000s SC, Fischer Panda Panda_4000s, Farymann 18W430 engine

Before you start

  • Do not disconnect the battery during operation.

Procedure

  1. Connect positive battery cable directly to solenoid switch of starter; use prepared protective tube.
  2. Connect negative battery cable to connection point at engine foot.
  3. Install a right-sized fuse in positive battery line as close as possible to battery, maximum 12 inch or 300 mm.
  4. Use multi-core stranded wire only; protect cable from heat, vibration and chafing.
  5. Check battery cable after installation for possible damage.

Specs & values

  • Battery capacity at least 44Ah
  • Cable cross-section 25mm²
  • Fuse maximum 12 inch or 300 mm from battery

Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.