Procedure

  1. Guarantee that connection to the electrical system is interrupted.
  2. Remove all conductors in the power terminal box of the generator.
  3. Connect starter battery to generator.
  4. Start the generator.
  5. Measure voltage between phase(s) and N with a voltmeter.
  6. If measured values are substantially below Table E.2.1 values, accept coil damage.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Voltage stator coil single-phase L-N: 2-4V

Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.