Fischer Panda — Adjustment of the maximum upper speed
Adjustments · actuator/VCS
From a Fischer Panda service manual covering: AGT-DC 10000, AGT10.000-24, PMS AGT-DC 10000, Panda PMS AGT-DC 10000. Check it applies to your exact model before use.
Applies to: Fischer Panda AGT-DC 10000, Fischer Panda Panda PMS AGT-DC 10000, Kubota D722 engine
Before you start
- This adjustment should not be changed; otherwise warranty expires.
Procedure
- Disconnect actuator electrical supply plug.
- Unclamp countering nut at limitation screw with SW 10 wrench.
- Connect voltmeter up to 100 V DC to clamps 7 and 8 of VCS.
- Ensure no electrical load is applied.
- Start generator.
- Turn actuator spindle manually until voltmeter reads 33 V.
- Tighten limit stop screw against speed regulator lever.
- Secure limit stop screw with countering nut.
- Check voltage is limited to max. 33 V without load.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Max. 33 V without load
Full service-parts list: Fischer Panda AGT-DC 10000 →, Fischer Panda Panda PMS AGT-DC 10000 →, Kubota D722 engine →
Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.