Home›Repair guides›Fischer Panda›Insulation test

Fischer Panda 4000s SC / Panda 4K PMS — Insulation test

Installation · AC electrical system

For the Fischer Panda 4000s SC / Panda 4K PMS, from the Fischer Panda owner's manual.

Applies to: Fischer Panda 4000s SC, Fischer Panda Panda 4K PMS, Kubota Z482 engine

Before you start

  • Electrical voltages above 48 volts are dangerous to life.

Procedure

  1. Switch off all on-board electrical devices.
  2. Start the generator.
  3. Measure AC voltage between generator housing and AC-Control box.
  4. Measure AC voltage between generator housing and ground.
  5. Measured voltage must not exceed 50 mV.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Maximum 50 mV

Full service-parts list: Fischer Panda 4000s SC →, Fischer Panda Panda 4K PMS →, Kubota Z482 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.