Home›Repair guides›Fischer Panda›Check and discharge the capacitors

Fischer Panda 4000s SC / Panda 4K PMS — Check and discharge the capacitors

Maintenance

For the Fischer Panda 4000s SC / Panda 4K PMS, from the Fischer Panda owner's manual.

Applies to: Fischer Panda 4000s SC, Fischer Panda Panda 4K PMS, Kubota Z482 engine

Before you start

  • Charged capacitors can be lethal.
  • Never check capacitors while the generator motor is running.

Procedure

  1. Switch off generator and remove starter battery.
  2. Open the AC-Control Box.
  3. Bridge capacitor contacts with insulated screwdriver to discharge.
  4. Measure capacity with multimeter set to capacitor measuring.
  5. Check all capacitors in the electrical cabinet.

Tools required

  • multimeter with capacitor measuring Amazon
  • insulated screwdriver Amazon
  • discharge reactor 5-10kOhm Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Fischer Panda 4000s SC →, Fischer Panda Panda 4K PMS →, Kubota Z482 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.