Home›Repair guides›Fischer Panda›Starting the Generator

Fischer Panda 3.5e / PMS 5.5e — Starting the Generator

Operation

For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.

Applies to: Fischer Panda PMS 5.5e

Before you start

  • If the generator fails to start after more than four attempts, raw water may enter the engine through the exhaust manifold. Damage from water ingestion is not covered under warranty.

Procedure

  1. Open raw water valve.
  2. Press and release the On/Off button on the control panel.
  3. Verify on the control panel that no values display '---' by cycling through screens.
  4. Press and release the Start/Stop button; the engine automatically preheats for 0 to 20 seconds.
  5. The starter engages; the control system disengages it once the engine starts.
  6. If the generator fails to start, the shutdown message 'Start Attempt Failed' is displayed.

Specs & values

  • Engine preheat 0 to 20 seconds

Full service-parts list: Fischer Panda PMS 5.5e →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.