Fischer Panda 3.5e / PMS 5.5e — Starting the Generator
Operation
For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.
Applies to: Fischer Panda PMS 5.5e
Before you start
- If the generator fails to start after more than four attempts, raw water may enter the engine through the exhaust manifold. Damage from water ingestion is not covered under warranty.
Procedure
- Open raw water valve.
- Press and release the On/Off button on the control panel.
- Verify on the control panel that no values display '---' by cycling through screens.
- Press and release the Start/Stop button; the engine automatically preheats for 0 to 20 seconds.
- The starter engages; the control system disengages it once the engine starts.
- If the generator fails to start, the shutdown message 'Start Attempt Failed' is displayed.
Specs & values
- Engine preheat 0 to 20 seconds
Full service-parts list: Fischer Panda PMS 5.5e →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.