Fischer Panda 3.5e / PMS 5.5e — Recommissioning
Maintenance · Generator
For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.
Applies to: Fischer Panda PMS 5.5e
Procedure
- Reconnect raw water hoses.
- Remove tape on air intakes and exhaust.
- Charge batteries and reconnect.
- Install raw water impeller.
- Perform any scheduled preventative maintenance not performed before long-term storage.
- Turn the engine over by hand for a couple of revolutions.
- Perform Pre-operational Checks (Section 3.1).
- Start engine and check for exhaust, fuel, and water leaks.
Full service-parts list: Fischer Panda PMS 5.5e →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.