Home›Repair guides›Fischer Panda›Preoperational Checks

Fischer Panda 3.5e / PMS 5.5e — Preoperational Checks

Maintenance · Generator

For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.

Applies to: Fischer Panda PMS 5.5e

Before you start

  • Hot engine components and coolant may cause severe burns. Do not touch the generator while it is hot.

Procedure

  1. Make sure generator is shut down.
  2. Remove the generator capsule top.
  3. Inspect for leaks at hoses, hose connections, fuel filter, coolant pump, raw water pump, and exhaust.
  4. Check engine oil level; keep to the maximum on the dipstick.
  5. Check coolant level in the expansion tank.
  6. Visually inspect motor and generator mounting screws for tightness.
  7. Check the sea strainer for debris and clean as necessary.
  8. Reinstall the capsule top and check the fuel level.

Full service-parts list: Fischer Panda PMS 5.5e →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.