Home›Repair guides›Fischer Panda›Long Term and Winter Storage

Fischer Panda 3.5e / PMS 5.5e — Long Term and Winter Storage

Maintenance · Generator

For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.

Applies to: Fischer Panda PMS 5.5e

Before you start

  • Observe local regulations for the disposal of antifreeze.

Procedure

  1. Add the correct amount of diesel stabilizer to the fuel tank.
  2. Check engine coolant mixture for the lowest temperature expected.
  3. Run generator 15 minutes with fresh water, then 5 minutes with non-toxic anti-freeze.
  4. Remove impeller to completely drain water; replace with a new impeller.
  5. Change engine oil and filter; change fuel filters.
  6. Charge batteries and disconnect; fill diesel tank to prevent condensation.
  7. Close all generator seacocks; apply low-tack duct tape to intake hose and exhaust outlet.
  8. Drain raw water system if below freezing; clean and dry any moisture in the capsule.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Stored greater than 3 months or below freezing temperatures

Full service-parts list: Fischer Panda PMS 5.5e →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.