Fischer Panda 3.5e / PMS 5.5e — Coolant Bleeding
Maintenance · Coolant system
For the Fischer Panda 3.5e / PMS 5.5e, from the Fischer Panda operator's manual.
Applies to: Fischer Panda PMS 5.5e
Before you start
- Hot engine components and coolant may cause severe burns. Do not open the coolant expansion tank if the generator is hot.
Procedure
- Ensure the engine is cool.
- Remove the coolant expansion tank cap and lower the tank below the bleed screw level.
- Open the bleed point; gravity will push coolant from the engine into the tank.
- Raise the expansion tank above the thermostat housing; do not let the tank empty.
- Observe the bleed point; close once only coolant (no air bubbles) flows.
- Secure the expansion tank cap.
- Run the generator for one minute.
- Repeat the bleeding process two more times to ensure all air is removed.
Full service-parts list: Fischer Panda PMS 5.5e →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.