Home›Repair guides›DuroMax›Starting the Generator Using Gasoline

DuroMax XP15000EH — Starting the Generator Using Gasoline

Operation · engine

For the DuroMax XP15000EH, from the DuroMax owner's manual.

Applies to: DuroMax XP15000EH

Before you start

  • Operating starter more than 5 seconds can damage the motor
  • Disconnect all electrical loads before starting

Procedure

  1. Shut breaker off
  2. Turn gas valve on
  3. Close choke
  4. Check fuel select switch set to GAS
  5. Turn engine switch to START, release to ON when started
  6. Open choke
  7. Turn breaker on
  8. Connect devices starting with largest loads first

Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.