DuroMax XP15000EH — Changing/Inspecting the AVR
Repair & overhaul · generator
For the DuroMax XP15000EH, from the DuroMax owner's manual.
Applies to: DuroMax XP15000EH
Procedure
- Remove 2 bolts of AVR located behind power panel
- Remove back cover, cut zip ties to brush system
- Disconnect wire clip
- Reconnect AVR wire to brush system
- Replace rear cover
- Bolt new replacement AVR onto back of power panel
Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.