Denyo — Booster Cable Connection and Battery Jump Start
For these Denyo models: DCA-220ESM, DF-2400M.
Applies to: Denyo DCA-220ESM, Denyo DF-2400M
Before you start
- Make sure terminal + does not touch terminal - when connecting booster cables
- Use booster cables and clips of the size that matches the size of battery
- The battery used for normal machine should be the same in capacity as the battery of the machine in trouble
- Clips must be firmly connected after connection
Procedure
- Connect the clip of the booster cable A to the terminal + of the normal machine battery.
- Connect the clip of the booster cable A to the terminal + of the battery of the machine in trouble.
- Connect the clip of the booster cable B to the terminal - of the battery of the normal machine.
- Connect the other clip of the booster cable B to the engine block of the machine in trouble. The engine block should be connected at a place more than 30cm away from the battery.
- Start the normal machine engine first and run it for a few minutes.
- Start the engine of the machine in trouble. Once the engine starts, run both engines for a few more minutes.
- Remove the clip of the booster cable A connected to the engine block of the machine in trouble.
- Remove the clip of the booster cable A connected to the terminal + of the normal machine.
- Remove the clip of the booster cable B connected to the terminal - of the normal machine.
- Remove the clip of the booster cable B connected to the engine block of the machine in trouble.
Tools required
- Booster cables with clips
Specs & torque values
- Battery capacity should match between normal machine and machine in trouble
- Engine block connection should be more than 30cm away from battery
Source: manual:DCA-220ESM.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.