Cummins/Onan — Vibration Isolators Installation and Adjustment Procedure
Installation
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan DQKB, Cummins/Onan DQKC, Cummins/Onan QSK60 engine
Procedure
- Place the vibration isolators on the genset support structure.
- Shim or grout so all isolator bases are within 0.25 inch (6 mm) elevation of each other.
- Loosen side snubber lock nuts so top plate moves vertically and horizontally.
- Place genset onto isolators, aligning skid mounting with threaded isolator hole.
- Insert leveling bolt through skid into isolator to adjust clearance.
- Adjust leveling bolt to obtain 0.25 inch (6 mm) or greater clearance.
- Adjust leveling bolts until set is level with roughly equal clearance on all isolators.
- Lock leveling bolt in place with lock nut.
- Leave snubber nuts loose to provide better isolation.
Specs & values
- 0.25 inch (6 mm) nominal clearance
Full service-parts list: Cummins/Onan DQKB →, Cummins/Onan DQKC →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.