Home›Repair guides›Cummins/Onan›Troubleshoot - Excessive Smoke Under Load (Overload Condition)

Cummins/Onan — Troubleshoot - Excessive Smoke Under Load (Overload Condition)

Testing & diagnosis · Fuel / Intake

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKBH

Procedure

  1. Step 01: evaluate fault codes
  2. Step 01: check fuel supply and fuel filters
  3. Step 02: check intake restriction
  4. Step 02: check fuel flow
  5. Step 02: check governor actuator operation

Specs & values

  • SRT 00-046: 0.5 hr step 01; 0.7 hr step 02; in-chassis accessibility B

Full service-parts list: Cummins/Onan MDKBH →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →