Home›Repair guides›Cummins/Onan›Testing L21 Reactor

Cummins/Onan — Testing L21 Reactor

Testing & diagnosis · L21 commutating reactor

From a Cummins/Onan service manual covering: 300.0 DFT, 350.0 DFU, 350.0 WF, 400.0 DFV, 400.0 WK, 450.0 DFW, 500.0 DFY, 600.0 DWV. Check it applies to your exact model before use.

Applies to: Cummins/Onan YB series

Procedure

  1. L21 mounts inside control box, below VR21 voltage regulator.
  2. Coils 1-2 and 3-4 are wound on the same core.
  3. Resistance between 1-2 and 3-4 should be equal.
  4. Resistance between coils (e.g., 1-4) or from any terminal to frame should be infinity.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Resistance between 1-2 and 3-4 equal
  • Resistance between coils or to frame infinity

Full service-parts list: Cummins/Onan YB series →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.