Home›Repair guides›Cummins/Onan›Testing Field Flash

Cummins/Onan — Testing Field Flash

Testing & diagnosis · generator field

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKB, Cummins/Onan MDKBH

Procedure

  1. Disconnect the governor actuator leads to keep the engine from starting.
  2. Measure output voltage while cranking.
  3. If output voltage increases at least 1 volt while cranking, the field excitation system is probably in working order.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Output voltage increase of at least 1 volt while cranking

Full service-parts list: Cummins/Onan MDKB →, Cummins/Onan MDKBH →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.