Home›Repair guides›Cummins/Onan›Testing Commutating Reactors (L21 and L22)

Cummins/Onan — Testing Commutating Reactors (L21 and L22)

Testing & diagnosis

From a Cummins/Onan service manual covering: DL4, DL6, DL6T. Check it applies to your exact model before use.

Applies to: Cummins/Onan DL4, Cummins/Onan DL6, Cummins/Onan DL6T

Procedure

  1. Remove reactor leads from terminal board for testing.
  2. Measure resistance between coils 1-2 and 3-4; should be 0.031-0.37 and 0.037-0.46 ohms at 77 deg F (25 deg C).
  3. Measure resistance between coils and from any terminal to frame; should be infinity.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Full service-parts list: Cummins/Onan DL6 →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.