Cummins/Onan — Starting Procedure - Manual Start Models
Operation · Generator Set
From a Cummins/Onan operator's manual covering: 2.0 EGHAM, 2.5 EGHAA, 3.5 EGHEM, 4.0 EGHAB, 4.0 EGHEB, 5.0 EGHAB, 5.0 EGHEB, 5.0 EGHEM, 6.0 EGHEB. Check it applies to your exact model before use.
Applies to: Cummins/Onan 2.5 EGHAA, Cummins/Onan 4.0 EGHAB, Cummins/Onan 5.0 EGHAB, Cummins/Onan 5.0 EGHEB, Cummins/Onan 6.0 EGHEB, Cummins/Onan Elite E140H engine, Cummins/Onan GH170 engine
Before you start
- Inhalation of exhaust gas can result in severe personal injury or death.
Procedure
- Open the fuel valve. On 4.0 kW sets and below, check that the speed control lever is in the high speed 'H' position.
- Set the choke lever to the CLOSE position. If the engine is warm, do not close the choke.
- On models with Idlematic switch (3.5 kW and above), place the switch in the OFF position before starting.
- Move the engine switch to the On position.
- With one hand steadying the set, grip the recoil handle and pull out smoothly and quickly. Repeat as necessary.
- Gradually open the choke as the engine warms; allow three to five minutes warm-up before applying load.
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.