HomeCummins/OnanCummins/Onan 5.0 EGHEB

Cummins/Onan 5.0 EGHEB Generator Set

The Cummins/Onan 5.0 EGHEB is a 5000 kW (5000 kVA) Gasoline standby generator set powered by a Cummins/Onan Elite E140H engine. It is available at 120 V and 240 V, Single-phase, 60 Hz and rated 45.8 A. It holds about 1 L (0.3 gal) of oil and 1.16 L (0.3 gal) of coolant, with a maximum ambient rating of 32 °C. Starting uses 1 group-12 battery rated 235 CCA at 12 V. The set measures 742×572×719 mm (29.2×22.5×28.3 in) and weighs about 84 kg (185 lb). An integrated tank holds 30.3 L (8.0 gal), roughly 9 hours of runtime.

5000 kW
Standby
0.39 L
Displacement
1.0 L
Oil capacity
2
Document types

How to read your Cummins/Onan serial & model number →

Compare with other 5000–5005 kW Gasoline generators →

Specifications

FuelGasoline
Frequency60.0 Hz
Standby power5000 kW
Standby kVA5000
Prime power41 kW
Oil capacity1.0 L
AlternatorCummins/Onan 5.0EGHEB
Voltage options120 V, 240 V
PhaseSingle
Rated current45.8 A
Power factor1-1
Circuit breaker22.9 A
Battery group12x10
Battery cranking235 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity1.16 L
Max ambient32 °C
Dimensions (L×W×H)742×572×719 mm
Dry weight84 kg
Fuel tank30.3 L
Tank runtime9 hr

Engine

Cummins/Onan Elite E140H
Oil capacity0.95 L
Displacement0.39 L
Rated speed3600 rpm

Maintenance & consumables

for the Cummins/Onan Elite E140H
ItemSpecCapacityPart #Interval
Air filterReplace air cleaner element400 hr find
Fuel filterReplace fuel filter200 hr find
Oil filterReplace oil filter according to local regulations400 hr find
BeltReplace belts as needed find
CoolantChange coolant as needed
OilAPI Class SG or SH oil (also SG/CD, SG/CE, SH/CD or SH/CE)200 hr

Common questions

What is the power rating of the Cummins/Onan 5.0 EGHEB?

The Cummins/Onan 5.0 EGHEB is rated 5000 kW standby (5000.0 kVA).

What engine does the Cummins/Onan 5.0 EGHEB use?

The Cummins/Onan 5.0 EGHEB is powered by the Cummins/Onan Elite E140H engine.

What fuel does the Cummins/Onan 5.0 EGHEB use?

The Cummins/Onan 5.0 EGHEB runs on Gasoline.

What is the oil capacity of the Cummins/Onan 5.0 EGHEB?

The Cummins/Onan Elite E140H engine in the Cummins/Onan 5.0 EGHEB has an oil capacity of 0.95 liters.

What alternator does the Cummins/Onan 5.0 EGHEB use?

The Cummins/Onan 5.0 EGHEB uses a Cummins/Onan 5.0EGHEB alternator.

Troubleshooting

12

Symptoms & remedies

SymptomCauseRemedy
FAILS TO CRANK (ELECTRIC START MODELS)Low Battery, Bad battery connection, Oil is too heavy, Load is connectedCheck battery electrolyte level and charge. Clean and tighten all battery and cable connections. Replace with lighter oil. Always disconnect load while starting.
CRANKS SLOWLY (ELECTRIC START MODELS)Choke closed, Dirty air filter, Rich fuel mixtureOpen choke. Clean or replace air filter. Contact an Onan service center.
ENGINE WONT STARTLoose or worn spark plug lead, Faulty spark plug, Dirty fuel filter or generator set at too steep of an angle, Governor out of adjustment or lean fuel mixCheck spark plug lead connection. Remove and clean or replace spark plug. Check fuel filter and generator set angle. Contact an Onan service center.
EXHAUSTING BLACK SMOKEOpen DC circuit breaker due to an overloadRemove all loads, reset circuit breaker, check for an overload or short circuit. Do not exceed generator set rated load specifications.
UNIT RUNS THEN STOPSAdd fuel. Add oil. Reduce oil level.
UNIT RUNS BUT SURGESAdd fuel. Add oil. Reduce oil level.
NO AC OUTPUT VOLTAGEOpen AC circuit breaker due to an overloadRemove all loads, re-set circuit breaker, check tools or appliances being used for defects. Do not exceed generator set rated load specifications.
FAILS TO CRANK1. Low battery. 2. Bad battery connection.1. Check battery electrolyte level. 2. Clean and tighten all battery and cable connections.
CRANKS SLOWLY1. Low battery. 2. Bad battery connection.1. Check battery electrolyte level. 2. Clean and tighten all battery and cable connections.
ENGINE WON’T START1. Fuel below genset pickup level in tank. 2. Fuel supply shutoff valve closed. 3. Remove spark plug and clean. 4. Add oil if necessary.1. Add fuel. 2. Fully open fuel supply valve. 3. Replace with recommended oil. 4. Disconnect load while starting.
UNIT RUNS THEN SURGES1. Loose or worn spark plug lead 2. Faulty spark plug. 3. Dirty fuel filter or generator set at too steep of an angle. 4. Governor out of adjustment or lean fuel mixture.1. Check spark plug lead connection. 2. Remove and clean or replace. 3. Check fuel filter and angle of generator set. 4. Contact an Onan service center.
NO DC OUTPUT VOLTAGE1. Open DC circuit breaker due to an overload.1. Remove all loads, reset breaker, check for shorted battery or load defects. Do not exceed rated load specifications.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

5
Part #DescriptionQtySystem
111-1802Fuel Fill1Fuel PartsGeek
LS1149Oil WatchService part / kit PartsGeek
M-1830-2AC Receptacle1Service part / kit PartsGeek
M-1833Oil Fill1Service part / kit PartsGeek
M-18344DC Receptacle1Service part / kit PartsGeek

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime100%0.92.5
Standby100%0.82.5

Available documents

Owner's manual — 981-0130 Onan EGH EGS Operator's Manual (2-1994) (Cummins/Onan)Service manual — 965-0100 Onan EGHxx series Portable genset Operator's manual (10-1995) (Cummins/Onan)