Cummins/Onan — Starting plant manually
Operation · starting crank
From a Cummins/Onan owner's manual covering: 10CW-150R, LOCW-150 R/, LOCW-3R/12 F. Check it applies to your exact model before use.
Applies to: Cummins/Onan 10CW-150R, Cummins/Onan Spec A, Cummins/Onan Spec B, Cummins/Onan Spec C, Cummins/Onan Spec D, Cummins/Onan Spec E, Cummins/Onan Spec F, Cummins/Onan Spec G
Before you start
- Do not spin the engine or push downward on the crank.
Procedure
- Adjust manual choke according to temperature.
- Prime fuel pump 10 to 20 strokes if initial run or plant ran out of fuel.
- Set toggle switch to HAND CRANK if electric-start model.
- Engage starting crank and pull quickly upward.
- Remove crank as soon as plant starts.
Tools required
- starting crank Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Cummins/Onan 10CW-150R →, Cummins/Onan Spec A →, Cummins/Onan Spec B →, Cummins/Onan Spec C →, Cummins/Onan Spec D →, Cummins/Onan Spec E →, Cummins/Onan Spec F →, Cummins/Onan Spec G →