Before you start

  • Disconnect battery before servicing to prevent accidental starting.

Procedure

  1. Connect jumper lead between battery positive (+) terminal and solenoid S terminal.
  2. Momentarily connect jumper between battery negative (-) and solenoid body.
  3. Solenoid contacts should close; replace solenoid if it does not activate.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.