Home›Repair guides›Cummins/Onan›Removing the Genset (Disconnecting)

Cummins/Onan — Removing the Genset (Disconnecting)

Installation

From a Cummins/Onan service manual covering: 5.5 HGJAA, 5.5 HGJAB, 5.5 HGJAC, 5.5 HGJAD, 5.5 HGJAE, 5.5 HGJAF, 6.5 HGJAA, 6.5 HGJAB, 6.5 HGJAC, 6.5 HGJAE, 6.5 HGJAF, 7.0 HGJAA…. Check it applies to your exact model before use.

Applies to: Cummins/Onan 5.5 HGJAD, Cummins/Onan 5.5 HGJAE, Cummins/Onan 6.5 HGJAE

Before you start

  • Arcing at battery terminals can ignite battery gas causing severe personal injury.
  • Gasoline and LPG are flammable and explosive and can cause severe personal injury or death.
  • LPG sinks and can accumulate in explosive concentrations.

Procedure

  1. Disconnect all battery cables (negative first) at the battery terminals.
  2. Disconnect the negative and positive battery cables at the genset.
  3. Disconnect the wiring connectors for remote control and remote fuel pump.
  4. Disconnect the generator AC output wires and conduit from the junction box.
  5. Disconnect the exhaust tail pipe.
  6. Gasoline models: disconnect the fuel line(s) and securely plug the ends.
  7. LPG models: close the fuel shutoff valve(s), move the vehicle outside and away from below-grade spaces, purge LPG, then disconnect and plug.

Full service-parts list: Cummins/Onan 5.5 HGJAD →, Cummins/Onan 5.5 HGJAE →, Cummins/Onan 6.5 HGJAE →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.