Home›Repair guides›Cummins/Onan›Starting the Engine

Cummins/Onan PX12000e — Starting the Engine

Operation · generator

For the Cummins/Onan PX12000e, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan PX12000e, Cummins/Onan EH65D engine

Before you start

  • Do not start the generator with electrical appliances connected and switched on.

Procedure

  1. Check the oil level before each operation and perform the specified Daily Inspection.
  2. Make sure that the no-fuse breaker is off.
  3. Turn the fuel cock to the vertical (open) position.
  4. Turn the starter switch to the START position.
  5. If the engine won't start, turn the switch back to ON and wait approximately 10 seconds before trying again.
  6. Warm the engine up for a minute or two before connecting loads.

Specs & values

  • Starter may need to run at least 3 to 5 seconds

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.