Cummins/Onan PX12000e — Starting the Engine
Operation · generator
For the Cummins/Onan PX12000e, from the Cummins/Onan operator's manual.
Applies to: Cummins/Onan PX12000e, Cummins/Onan EH65D engine
Before you start
- Do not start the generator with electrical appliances connected and switched on.
Procedure
- Check the oil level before each operation and perform the specified Daily Inspection.
- Make sure that the no-fuse breaker is off.
- Turn the fuel cock to the vertical (open) position.
- Turn the starter switch to the START position.
- If the engine won't start, turn the switch back to ON and wait approximately 10 seconds before trying again.
- Warm the engine up for a minute or two before connecting loads.
Specs & values
- Starter may need to run at least 3 to 5 seconds
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.