For the Cummins/Onan PX12000e, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan PX12000e, Cummins/Onan EH65D engine

Procedure

  1. Remove the knob and air cleaner cover.
  2. Remove the paper inner element and urethane foam outer element.
  3. Wash and clean the urethane foam in kerosene; saturate in 3 parts kerosene and 1 part engine oil, then squeeze out excess oil.
  4. Clean the paper element by tapping gently to remove dirt and blowing off dust; never use oil.
  5. Set the elements on the air cleaner base with the grommet in position and install the cover with knob tightened securely.

Specs & values

  • Clean or replace every 50 hours (more often in dusty environments)
  • Replace element set every 200 hours or once a year

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.