Home›Repair guides›Cummins/Onan›Connecting to Domestic Circuit (House Wiring)

Cummins/Onan PX12000e — Connecting to Domestic Circuit (House Wiring)

Installation · transfer switch and house wiring

For the Cummins/Onan PX12000e, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan PX12000e, Cummins/Onan EH65D engine

Before you start

  • All connections must be made by a licensed electrician.
  • Failure in connection may result in death, personal injury, damage to generator, damage to appliances, damage to building's wiring or fire.
  • Do not connect the generator to a commercial power line.

Procedure

  1. When connecting the generator to house wiring, take generator output power from the 240V-4P receptacle.
  2. Install a transfer switch of the correct capacity between the meter and the fuse or AC breaker box.
  3. If the neutral wire of house wiring is grounded, be sure to ground the ground terminal of the generator.
  4. Turn the house AC breaker off before starting the generator.
  5. Start the generator and warm it up, then turn the house AC breaker on.

Specs & values

  • Use a transfer switch of the correct capacity
  • Generator is neutral grounded type

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.