From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKUB, Cummins/Onan MDKWB, Kubota Z482B engine, Kubota D722B engine

Before you start

  • The neoprene impeller must never be run dry.

Procedure

  1. Remove the outlet hose at the pump connection.
  2. Fill the pump with water and replace components.
  3. When the genset is started, check the exhaust outlet for delivery of water to the system.

Full service-parts list: Cummins/Onan MDKUB →, Cummins/Onan MDKWB →, Kubota Z482B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.