Cummins/Onan — Preparation for Storage
Maintenance · generator
From a Cummins/Onan operator's manual covering: EGMBM / PX6100, PX6100/e, RGV2800, RGV4100. Check it applies to your exact model before use.
Applies to: Cummins/Onan RGV2800, Cummins/Onan RGV4100, Mitsubishi EH17-2D engine, Mitsubishi EH25-2D engine
Before you start
- NEVER USE WATER TO CLEAN GENERATOR!
Procedure
- Drain fuel from fuel tank carefully by disconnecting the fuel line.
- Remove the carburetor float chamber and also drain the carburetor.
- Change engine oil.
- Check for loose bolts and screws, tighten them if necessary.
- Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR!
- Pull starter handle until resistance is felt, leaving handle in that position.
- Store generator in a well ventilated, low humidity area.
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.