The Mitsubishi EH25-2D is an engine. It powers generator sets from Cummins/Onan, including the RGV4100. It holds 1 L (0.3 gal) of oil.
Also known as: Mitsubishi Heavy Industries EH25-2D
| Oil capacity | 1.0 L |
|---|
Compiled from service & troubleshooting documentation across every generator set that uses the Mitsubishi EH25-2D.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| air cleaner element | Clean | 50 hr | Daily inspection: clean air cleaner element | |
| bolts and nuts | Check | 8 hr | Every 8 hours (Daily) | |
| engine | Check | 8 hr | Daily inspection: excessive vibration, noise | |
| engine oil | Check | 8 hr | Refill daily up to upper level (Daily) | |
| fuel and oil leakage | Check | 8 hr | Daily inspection: leakage of gasoline and engine oil | |
| gasoline | Check | 8 hr | Daily inspection: enough gasoline | |
| generator | Clean | 8 hr | Every 8 hours (Daily) | |
| surroundings | Check | 8 hr | Daily inspection: safe surroundings | |
| engine oil | Change | 100 hr | First service — Thereafter change oil every hundred (100) hours | |
| spark arrester | Clean | 100 hr | Clean spark arrester every hundred (100) hours | |
| air cleaner element | Replace | 200 hr | Replace element set every 200 hours | |
| fuel lines | Replace | 1000 hr | 12 mo | Replace the fuel hose every 1,000 hours or every year |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Spark plug electrode gap | 0.02 to 0.03 in. (0.6 to 0.7 mm) | ||
| Gap | Spark plug electrode gap | 0.03 in. (0.7 to 0.8 mm) | ||
| Valve clearance | Valve clearance (Intake and Exhaust) | 0.0039±0.0006 in (0.1±0.015 mm) | cold | |
| Valve clearance | Valve clearance (Intake and Exhaust) | 0.0039±0.0012 in (0.1±0.03 mm) | cold |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | SAE 10W-30 or 10W-40 | API service class SE or higher grade (SG, SH or SJ is recommended) | If single viscosity oil is used, select the appropriate viscosity for the average temperature in your area. Oil capacity: RGV2800 0.65 liter; RGV4100 1.0 liter; PX6100/e 1.2 liter. | ||
| Fuel | Automotive unleaded gasoline |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Death, personal injury and/or property damage may occur unless instructions are followed carefully.
⚠ Failure in connection may result in death, personal injury, damage to generator, damage to appliances, damage to the building's wiring or fire.
⚠ A transfer switch must be installed by a certified/licensed electrician to transfer the load from the commercial power source to the generator.
⚠ Do not wash elements with kerosene, gasoline or oil.
⚠ Gasoline is flammable.
Tools: plug cleaner, wire brush
⚠ Change engine oil every 100 hours. For new engine, change oil after 20 hours.
⚠ Take extreme caution when replacing fuel hose; gasoline is flammable.
⚠ NEVER USE WATER TO CLEAN GENERATOR!
⚠ Do not run the starting motor over 5 seconds continuously.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
The Mitsubishi EH25-2D engine has an oil capacity of 1.0 liters.
The Mitsubishi EH25-2D powers 1 generator set(s), including Cummins/Onan RGV4100.
A commonly reported issue on generators using the Mitsubishi EH25-2D is: When No Electricity Is Generated at Receptacle :. Fix: Check to make sure no-fuse breaker is in the "ON" position. Check AC and DC terminals for loose connection. Check to see if engine starting was attempted with appliances already connected to generator. After making sure that the total wattage of the electrical appliance is within permissible limits and there are no defects in the appliance, turn the no-fuse breaker to the "ON" position. If breakers continue to actuate, consult your nearest servicing dealer. Secure connection if necessary. Turn off switch on the appliance, and disconnect cable from receptacle. Reconnect after generator has been started properly..