Home›Repair guides›Cummins/Onan›Emergency Stop Reset at Control Panel (Code 102)

Cummins/Onan PCC 3100 — Emergency Stop Reset at Control Panel (Code 102)

Operation · Emergency stop button

For the Cummins/Onan PCC 3100, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan DFHA, Cummins/Onan DFHB, Cummins/Onan DFHC, Cummins/Onan DFHD, Cummins/Onan PCC 3100, Cummins/Onan QST30 engine

Before you start

  • Emergency Stop shutdown status (Code 102) can be reset only at the PCC front panel.

Procedure

  1. Pull the button out or turn the button clockwise (button with arrow) and allow it to pop out.
  2. Move the Run/Off/Auto switch to the Off position.
  3. Press the front panel Reset switch.
  4. Select Run or Auto, as required.

Full service-parts list: Cummins/Onan DFHA →, Cummins/Onan DFHB →, Cummins/Onan DFHC →, Cummins/Onan DFHD →, Cummins/Onan PCC 3100 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →