Cummins/Onan NTA855 — Starting at Control Panel (PCC)
Operation · PowerCommand Control 3100
For the Cummins/Onan NTA855, from the Cummins/Onan operator's manual.
Applies to: Cummins/Onan DFBF, Cummins/Onan DFCB, Cummins/Onan DFCC, Cummins/Onan DFCE, Cummins/Onan DQBA, Cummins/Onan DQBB, Cummins/Onan NTA855, Cummins/Onan NT855 engine, Cummins/Onan NTA855 engine, Cummins/Onan N14 engine
Procedure
- Move the Run/Off/Auto switch to the Run position.
- Starter begins cranking; after a few seconds the engine starts and the starter disconnects.
- If engine does not start, the control indicates an overcrank shutdown.
- To clear overcrank, place Run/Off/Auto switch in Off and momentarily press Reset.
- Wait two minutes for the starter motor to cool, then repeat.
Specs & values
- Cycle cranking: crank/rest 7 to 20 seconds individually preset; 3, 4, or 5 cycles
- Continuous cranking up to 75 seconds
Full service-parts list: Cummins/Onan DFBF →, Cummins/Onan DFCC →, Cummins/Onan DFCE →, Cummins/Onan DQBA →, Cummins/Onan DQBB →
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.