Home›Repair guides›Cummins/Onan›Mount Remote Start-Stop-Preheat Panel

Cummins/Onan — Mount Remote Start-Stop-Preheat Panel

Installation · Remote control panel

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKUB, Cummins/Onan MDKWB, Kubota Z482B engine, Kubota D722B engine

Before you start

  • The electrical code does not allow the remote-control harness or wiring to be routed in the same conduit with AC wiring.
  • Be sure to seal all openings made for the wiring so exhaust or fuel vapors cannot enter the living quarters.

Procedure

  1. Unscrew the two hold-down screws that hold the panel in place.
  2. Remove and discard the short 6” wiring harness connecting control panel P1 to genset J1.
  3. Disconnect the leads that connect the running time meter to the terminal block inside the control box.
  4. Replace the short harness with a longer harness that will reach the control panel mounting location.
  5. Route the harness through the opening at the side of the control box.
  6. Use the blank panel provided with the set to cover the space where the removable control panel had been.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • harness lengths 15, 25 and 45-foot

Full service-parts list: Cummins/Onan MDKUB →, Cummins/Onan MDKWB →, Kubota Z482B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.