Home›Repair guides›Cummins/Onan›Membrane Switch Test

Cummins/Onan — Membrane Switch Test

Testing & diagnosis · Membrane switches

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan OTPC

Procedure

  1. Remove the connector from J25 on the Digital Module circuit board.
  2. Press the switch down and measure the resistance between the switch common (pin 10) and each switch at the solder points on the connector.
  3. The resistance of a closed membrane switch should be in the range of 0 to 200 ohms depending on how hard you press.
  4. Attach the connector to J25.
  5. Close and lock the enclosure door.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Closed membrane switch resistance: 0 to 200 ohms

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.