Cummins/Onan M-1902s — Installation of Line Circuit Breakers in 50 Hz Generator Set

Installation

For the Cummins/Onan M-1902s, from the Cummins/Onan service manual.

Applies to: Cummins/Onan HDKA, Kubota V1505-E3BG engine

Before you start

  • Only a qualified electrician should make this installation.
  • Be sure to disconnect the starting battery ground cable to prevent accidental starting.

Procedure

  1. If set not yet installed, go to step 6; otherwise continue.
  2. Park the RV on as level a surface as possible; lock brakes and remove ignition key.
  3. Disconnect the generator set starting battery ground (-) cable at the battery.
  4. Remove the cover from the genset control box on the generator set.
  5. Mount the circuit breaker assembly in the control box using screws and washers.
  6. Connect generator output leads L1, L2, and L3 to the circuit breaker (CB22).
  7. Run RV neutral lead and genset neutral lead to ground connection inside control box.
  8. Connect green leads from genset and RV to ground connection and tighten 1/4-20 screw.
  9. Secure conduit(s) to control box and reconnect the battery ground cable.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Connect L1, L2, L3 to breaker CB22; see AC wiring diagram page 11-4

Full service-parts list: Cummins/Onan HDKA →, Kubota V1505-E3BG engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.