Cummins/Onan — Installing Coolant Recovery Tank
Installation
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan MDKAL, Kubota D1005 engine
Procedure
- Use the bracket as a template to locate mounting holes.
- Allow at least 2 inches (51 mm) from tank top to any upper structure.
- Use hose from kit between engine overflow and tank connector.
- Route drain tube end to the drip pan to avoid coolant spills to bilge.
- Locate tank so hose is pitched slightly downward.
Full service-parts list: Cummins/Onan MDKAL →, Kubota D1005 engine →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.