- Install the J/W outlet tube bracket to the skid using two M8 x 25 mm screws.
- If necessary, loosen clamp to adjust engine water inlet tube (LTA) so outlet faces the radiator.
- Slide radiator hose all the way on both ends of each tube; apply lubricant (WD40 or soap/water).
- Open hose clamps so they slip over radiator hose and onto mating tubes on engine and radiator.
- Move tube into position and slide hose over top mating tube; tighten clamps.
- Slide radiator hose over bottom mating tube and tighten clamps.
- Tighten clamps on both ends of all tubes to 90-105 inch-lbs (10-12 N-m).
- Install the tube clamp on J/W outlet tube to the bracket installed in Step 1.