Home›Repair guides›Cummins/Onan›Initial Start and Check

Cummins/Onan — Initial Start and Check

Operation · Generator set

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKUB, Cummins/Onan MDKWB, Kubota Z482B engine, Kubota D722B engine

Before you start

  • Exhaust gas is deadly. Shut down the generator set immediately if an exhaust leak or exhaust component needs repair.
  • Do not operate the generator set after a high exhaust temperature shutdown until the entire exhaust system has been checked and serviced as required.

Procedure

  1. Make sure the fuel shutoff valve and raw water cock are open.
  2. Start the genset by holding the Start/Stop switch in Start position.
  3. The genset should start within a few seconds.
  4. Check water flow at the hull exhaust outlet, and operation of the genset.
  5. Check the exhaust system for leaks—visually and audibly.
  6. Check the genset for fuel, oil and coolant leaks.
  7. Connect an accurate AC voltmeter and frequency meter across two line terminals.
  8. Apply load to the generator and check the output.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan MDKUB →, Cummins/Onan MDKWB →, Kubota Z482B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.