Home›Repair guides›Cummins/Onan›Hot Air Recirculation Test Method

Cummins/Onan — Hot Air Recirculation Test Method

Testing & diagnosis · Generator set installation

From a Cummins/Onan service manual covering: 5.5 HGJAA, 5.5 HGJAB, 6.5 HGJAA, 6.5 HGJAB, 7.0 HGJAA, 7.0 HGJAB. Check it applies to your exact model before use.

Applies to: Cummins/Onan HGJAA, Cummins/Onan HGJAB

Before you start

  • EXHAUST GAS IS DEADLY! Do not operate the generator set when the vehicle is parked indoors or where exhaust can accumulate.

Procedure

  1. Complete a representative installation.
  2. Set up a load bank to run the generator set at rated full load.
  3. Conduct test where ambient air temperature remains between 16 C and 38 C (60 F and 100 F).
  4. Measure temperatures with thermocouples not heavier than 0.21 mm2 (24 AWG).
  5. Measure ambient air temperature with a shielded thermocouple within 1.2 m (4 ft).
  6. Close all compartment doors and run at full load for at least an hour.
  7. Record temperatures at 15 minute intervals until they stabilize.

Tools required

  • Load bank Amazon
  • Thermocouples (max 0.21 mm2 / 24 AWG) Amazon
  • 50.8 mm (2 in) diameter white PVC piping shield Amazon
  • Temperature recorder Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Temperature is considered stable when there is no change in 3 consecutive readings
  • Rise over ambient exceeding 15 C (27 F) must be repaired/modified

Full service-parts list: Cummins/Onan HGJAA →, Cummins/Onan HGJAB →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.