Home›Repair guides›Cummins/Onan›Starting the Generator Set

Cummins/Onan G1250s / M-1902s — Starting the Generator Set

Operation

For the Cummins/Onan G1250s / M-1902s, from the Cummins/Onan service manual.

Applies to: Cummins/Onan HDKA, Kubota V1305-B engine

Before you start

  • Shut down the generator set immediately if you discover an exhaust leak.

Procedure

  1. Hold the Start/Stop/Preheat switch in the Preheat position for 15 to 30 seconds.
  2. Hold the switch in the Start position; the engine should start within a few seconds.
  3. Monitor oil pressure, coolant temperature, and battery charge voltage.
  4. Check the exhaust system for leaks, visually and audibly.
  5. Check the generator set for fuel, oil or coolant leaks.
  6. Connect an AC voltmeter and frequency meter across two line terminals and apply load.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Preheat 15 to 30 seconds

Full service-parts list: Cummins/Onan HDKA →, Kubota V1305-B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.