| 1 | High engine coolant temperature | One blink indicates shutdown due to high engine coolant temperature. | Shutdown | Touch Stop to check the second-level fault code; it will be either No. 33 or No. 34. |
| 1, 2, 3, 4 | First level faults | First-level faults; avoid interpreting as second-level codes 11, 22, 33, or 44 | Shutdown | Pay close attention to the pause sequence |
| 11 | Overload Fault | Second-level shutdown code No. 11 (blink once, pause, blink once). Not assigned a first-level fault (avoid confusion with first-level Code 1). | Shutdown | Turn off the genset line circuit breaker; if the genset no longer shuts down, check for and repair a short in vehicle appliances, wiring or shorted battery charger transformer; check whether vehicle engine and genset share the same starting battery and increase battery capacity or install a separate battery. |
| 12 | Over Voltage | The control is unable to maintain rated voltage. | Shutdown | If the vehicle engine and genset share a starting battery, increase battery capacity or install a separate battery and charging system for the genset. |
| 13 | Under Voltage | The control is unable to maintain rated voltage. | Shutdown | Reduce load (especially air conditioners and battery chargers). |
| 14 | Over Frequency | The engine governor is unable to maintain rated frequency. | Shutdown | Reduce the number of connected appliances, especially when air conditioners and battery chargers are running. |
| 15 | Underfrequency Fault | The engine governor is unable to maintain rated frequency. | Shutdown | Reduce the number of connected appliances; have air conditioners and other appliances checked for proper operation (a locked compressor rotor can cause very low power factor). |
| 17 | Fuel Pump Fault | Controller sensed open circuit; bypassable fault prior to Spec F, discontinued beginning Spec F | Shutdown | Try priming by holding control switch at Stop; reconnect fuel pump leads; test pump on 12 V battery; check P1-2/E2-1 and E2-2/ground continuity. |
| 18 | Glow Plug Circuit Protection Fault | Controller sensed short circuit; bypassable fault prior to Spec F, discontinued beginning Spec F | Shutdown | Reconnect HR-1 to glow plug bus bar; check HR-1 and A1-J8 for ground short; replace engine harness or control assembly. |
| 19 | Governor Actuator Fault | The control sensed an open or shorted circuit. | Shutdown | See an authorized Onan dealer. |
| 2 | Low Oil Pressure (first-level fault) | Two blinks indicate shutdown due to a loss of engine oil pressure; oil pressure switch actuates below 9 psi (62 kPa) | Shutdown | Check oil level; check switch and wiring; replace switch or service engine if pressure <14 psi (98 kPa). |
| 21 | Starter Solenoid Circuit Protection Fault | Controller sensed short circuit; discontinued beginning Spec F | Shutdown | Reconnect K-1 to starter solenoid; test solenoid and starter; reconnect A1-J6; check continuity to ground; replace controller assembly. |
| 22 | Not assigned | The duration of operation is near full-duty cycle beyond design limit. | Warning | Step 01 (0.5 hr): check load, air intake restriction, exhaust restriction, air leak in fuel system, stator for opens/shorts. Step 02 (1.0 hr): check fuel flow test, governor for binding, high idle adjustment, injectors, injection pump timing, compression (SRT 00-0BL) |
| 23 | Low Oil Pressure Cutoff Switch Fault | Switch still open during start - not a running fault | Shutdown | See an authorized Onan dealer. |
| 24 | Throttle Control Fault | Engine throttle control malfunction | Shutdown | See an authorized Onan dealer. |
| 25 | Engine Sensor Fault | Governor unable to regulate to target speed. | Shutdown | See an authorized Onan dealer. |
| 26 | Engine Below Speed Target Fault | Governor unable to regulate to target speed. | Shutdown | Step 01 (0.5 hr): check loads, air in fuel system, air intake restriction, exhaust restriction. Step 02 (1.0 hr): check binding in the governor, high idle speed, injectors, injection timing, compression (SRT 00-0BQ) |
| 27 | Voltage Sense | The control is unable to sense output voltage. | Shutdown | Test with load bank to isolate load; check PMA-to-control connections; measure PMA lead voltages (T1-T2, T2-T3, T3-T1 - should exceed 20 Vrms); troubleshoot rotor/stator; replace control assembly. |
| 28 | DC Sense Lost Fault | Controller unable to sense DC bus voltage | Shutdown | Open the circuit breaker; if the fault does not persist, check for and disconnect excessive loads from the genset before starting. |
| 29 | High Battery Voltage Fault | Voltage across the battery system is greater than 19 Volts. | Warning | Check battery connections; measure DC voltage; check battery charger; verify ground at P1-7. |
| 3 | Service fault (second-level code follows) | Three blinks indicate a service fault; press Stop once to blink the two-digit second-level shutdown code (tens digit, pause, units digit) | Warning | Touch Stop to check the second-level fault code; it will be one of the codes in the troubleshooting table. |
| 31 | Overspeed Fault | Engine speed greater than 3600 rpm. | Shutdown | See an authorized Onan dealer. |
| 32 | Low Cranking Speed Fault | Cranking speed less than 180 rpm for more than 2 seconds; crank and generator frequency less than 3 Hz for greater than 2 seconds | Shutdown | Step 01 (0.3 hr): check fuse, harness connections to starter, battery connections at set and battery, battery voltage at set. Step 02 (0.7 hr): check starter operation, harness connection for opens/shorts, stator resistance for opens/shorts, rotor magnets for failure (SRT 00-0BS) |
| 33 | Not assigned | Second-level code 33 has not been assigned a fault | Shutdown | Step 01 (0.5 hr): verify FC is actually a secondary code; verify coolant level and fill if needed; verify engine coolant temperature; air inlet/outlet opening for blockage; excessive coach loads; coolant pump belt for wear; cooling fan for damage; housing air leaks. Step 02 (0.5 hr): check temperature sensor lead for opens/shorts; radiator blockage and clean. Step 03 (2.0 hr): clean and flush coolant system; replace coolant thermostat (SRT 00-0CS) |
| 34 | High Inverter Temperature Fault | Inverter heat sink temperature exceeded design limit. | Shutdown | Remove objects blocking the air inlet or outlet openings; reduce the number of appliances connected at the same time. |
| 35 | Control Card Fault | Microprocessor EPROM error during self-test. | Shutdown | Verify problem and report to factory (SRT 00-0CA, 0.2 hours) |
| 36 | Unknown Shutdown Fault | The engine stopped without receiving a command from the control. | Shutdown | Step 01 (0.3 hr): check fuel level in coach tanks, prime genset fuel system, air filter blockage, mechanical damage. Step 02 (0.5 hr): check auxiliary fuel pump, conduct fuel flow test, P1 and P2 connectors and wiring (SRT 00-0BW) |
| 37 | Invalid Genset Configuration Fault | The generator set control is not configured properly for the generator set | Shutdown | Verify problem and report to factory (SRT 00-CHA, 0.2 hours) |
| 38 | Overload Fault | Too many loads connected. | Shutdown | Step 01 (0.2 hr): reduce coach loads, cool inverter. Step 02 (1.0 hr): check if set has engine performance issue, fuel supply for sucking air, fuel flow test, governor operates smoothly, high idle speed, current transformer for shorts/opens (SRT 00-0BX) |
| 39 | Low Battery Voltage Fault | Prior to Spec F only | Warning | Inspect connections; check fuel/air leaks; avoid cranking propulsion engine; check battery voltage; replace/recharge battery. |
| 4 | Overcrank | Set cranked for 35 seconds without starting (speed >1200 RPM) (Begin Spec K) | Shutdown | Troubleshoot as an out-of-fuel condition (see FC36); check fuel flow and return, actuator operation, wiring. |
| 4 blinks | Cranking time exceeded 35 seconds | Status indicator light repeatedly blinks four times | Shutdown | Check fuel supply and priming before re-cranking |
| 41 | Generator Rotor | Control unable to sense field or output voltage | Shutdown | Contact local dealer or distributor. |
| 42 | Processor Fault | Microprocessor ROM error during self-test; beginning Spec F and replacement controller assemblies | Shutdown | Verify fault code (SRT 00-0CB, 0.2 hours) |
| 43 | Processor Fault | Microprocessor RAM error during self-test; beginning Spec F and replacement controller assemblies | Shutdown | Verify fault code (SRT 00-0CC, 0.2 hours) |
| 44 | Not assigned | Second-level code 44 has not been assigned a fault | | |
| 45 | Speed Sense | The control is unable to sense quadrature frequency. | Shutdown | Contact local dealer or distributor. |
| 46 | Inverter Power Supply Fault | Low battery voltage or power supply device failure; beginning Spec F and replacement controller assemblies | Shutdown | Verify fault code, voltage at set during cranking, voltage at starter during cranking, battery connections at set and battery, battery condition, set charging system if equipped (SRT 00-0BZ, 0.5 hours) |
| 48 | Generator Field Sense | The control is unable to sense field voltage. | Shutdown | Contact local dealer or distributor. |
| 57 | Over Prime | Priming exceeded 3 minutes. | Shutdown | Check for and remove any object holding either control switch in the STOP/PRIME position. |
| 8 | Overload (Models HDKAH & HDKAV only) | Starter or cranking circuit malfunction | Shutdown | Reduce load and restart. |
| restore | Restoring fault code blinking | Fault code stops blinking after five minutes | Info | Press Stop three times within three seconds to restore fault code blinking |