Cummins/Onan G1250s / M-1902s — Control Box Mounting

Installation · Genset control box

For the Cummins/Onan G1250s / M-1902s, from the Cummins/Onan service manual.

Applies to: Cummins/Onan HDKA, Kubota V1305-B engine

Before you start

  • Failure to mount the control box below 160° F (71.1° C) may cause equipment damage or failure.

Procedure

  1. Locate the control box in an area not contaminated by grease, oil, dust or dirt.
  2. Unscrew the bolts from the four vibration isolators supporting the control box.
  3. Drill holes of the appropriate size and place the box into position.
  4. Mount the toothed washers under the vibration isolators if the isolators are used.
  5. Plug the J2 and J1 harness connectors into the control box and route harnesses against the compartment walls.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Control box must be mounted where temperature is less than 160° F (71.1° C)

Full service-parts list: Cummins/Onan HDKA →, Kubota V1305-B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.