Home›Repair guides›Cummins/Onan›Fuel Solenoid Checkout (F)

Cummins/Onan — Fuel Solenoid Checkout (F)

Testing & diagnosis

From a Cummins/Onan service manual covering: DL4, DL6, DL6T. Check it applies to your exact model before use.

Applies to: Cummins/Onan DL4, Cummins/Onan DL6, Cummins/Onan DL6T

Procedure

  1. To check energized-to-run operation, listen for a click in injection pump when start switch is placed in run position.
  2. If no click and there is power to solenoid, the fuel solenoid must be replaced.
  3. To check energized-to-stop operation, listen for a click when switch is placed in stop position.
  4. If no click and there is no power to solenoid, the fuel solenoid must be replaced.

Full service-parts list: Cummins/Onan DL6 →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →