Repair & overhaul · Exciter field

From a Cummins/Onan service manual covering: 300.0 DFT, 350.0 DFU, 350.0 WF, 400.0 DFV, 400.0 WK, 450.0 DFW, 500.0 DFY, 600.0 DWV. Check it applies to your exact model before use.

Applies to: Cummins/Onan YB series

Before you start

  • Do not keep excitation circuitry connected longer than 5-seconds, or damage may occur to the exciter regulator.

Procedure

  1. Assemble six volt supply, resistor, and diode as shown in Figure 21.
  2. If six volt supply not available, a 12-volt can be used; substitute a 20-ohm resistor for the 10-ohm.
  3. Start the generator set.
  4. Touch positive lead to + on rectifier bridge, and negative lead to - terminal.
  5. Hold leads on terminals just long enough for voltage to build up.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan YB series →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.