Home›Repair guides›Cummins/Onan›Engine Torque Adjustment

Cummins/Onan — Engine Torque Adjustment

Adjustments · PowerCommand control

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan DFHA, Cummins/Onan DFHB, Cummins/Onan DFHC, Cummins/Onan DFHD, Cummins/Onan QST30 engine

Before you start

  • Calibration and adjustment must be performed by technically qualified personnel only

Procedure

  1. Select >> from the Main Menu to proceed to the Torque Adjust %DC menu.
  2. Start the generator set and allow it to reach normal operating speed.
  3. Load the generator set to maximum rated kVA at rated voltage.
  4. Adjust the torque limit up or down to achieve proper frequency under maximum load.
  5. Select SAVE to retain the adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Adjustable 0% to +1% of duty cycle units (about 0% to +2% engine horsepower)

Full service-parts list: Cummins/Onan DFHA →, Cummins/Onan DFHB →, Cummins/Onan DFHC →, Cummins/Onan DFHD →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.