Home›Repair guides›Cummins/Onan›Emergency Manual Mode Electrical Start

Cummins/Onan — Emergency Manual Mode Electrical Start

Operation · Engine starting system

From a Cummins/Onan owner's manual covering: 6CTA8.3, CFP83-F10, CFP83-F20, CFP83-F30, CFP83-F40. Check it applies to your exact model before use.

Applies to: Cummins/Onan 6CTA8.3, Cummins/Onan CFP83-F10, Cummins/Onan CFP83-F20, Cummins/Onan CFP83-F30, Cummins/Onan CFP83-F40, Cummins/Onan 6CTA8.3G2 engine, Cummins/Onan 6CTAA8.3G3 engine

Before you start

  • Use the lever on either solenoid. If one does not crank the engine, then use the other.

Procedure

  1. Open both manual valves in the raw water bypass supply piping.
  2. Press the MANUAL position on the AUTO/MANUAL rocker switch.
  3. Depress the lever on the selected solenoid to start the engine.
  4. Release the lever when the engine starts.
  5. Stop the engine by pressing the AUTO position on the AUTO/MANUAL rocker switch and then pressing the RESET switch.

Full service-parts list: Cummins/Onan CFP83-F10 →, Cummins/Onan CFP83-F20 →, Cummins/Onan CFP83-F30 →, Cummins/Onan CFP83-F40 →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.