Home›Repair guides›Cummins/Onan›Connecting to Domestic Circuits (House Wiring)

Cummins/Onan — Connecting to Domestic Circuits (House Wiring)

Installation · transfer switch

From a Cummins/Onan operator's manual covering: EGMBM / PX6100, PX6100/e, RGV2800, RGV4100. Check it applies to your exact model before use.

Applies to: Cummins/Onan RGV2800, Cummins/Onan RGV4100, Mitsubishi EH17-2D engine, Mitsubishi EH25-2D engine

Before you start

  • Failure in connection may result in death, personal injury, damage to generator, damage to appliances, damage to the building's wiring or fire.
  • A transfer switch must be installed by a certified/licensed electrician to transfer the load from the commercial power source to the generator.

Procedure

  1. When connecting a generator to a house wiring, generator output power must be taken from the 240V-4P receptacle.
  2. Install a transfer switch.
  3. If the neutral wire of house wiring is grounded, be sure to ground the ground terminal of the generator.
  4. Set the full power switch to 120V/240V side.
  5. Turn the house AC breaker off before starting the generator.
  6. Start the generator and warm it up.
  7. Turn the house AC breaker on.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.